Online Service
Tel : +86 13806035313
Email : randi@baysenmedical.com
H.Pylori antigent diagnostic test kit (Fluorescence Immunochromatographic Assay) is intended for in vitro qualitative detection of helicobacter pylori antigen in human stool sample, which is for evaluation of helicobacter pylori infection. This kit only provides detection result of helicobacter pylori antigen,and results obtained shall be used in combine with other clinical information for analysis.
Methodology:
Fluorescence Immunochromatographic AssayTesting time:
10-15 minutesStorage temperature ::
2℃-30℃Specimen::
Human stoolValid Time ::
24 monthAccurancy:
99%Specification:
25 test/boxDiagnostic Kit for Antigen to Helicobacter Pylori (Fluorescence Immunochromatographic Assay)
Model Number | HP-Ag | Packing | 25 Tests/ kit, 20kits/CTN |
Name | Diagnostic Kit for Helicobacter Pylori antigen (fluorescence immunochromatographic assay) | Instrument classification | Class II |
Features | High sensitivity, Easy opeation | Certificate | CE/ ISO13485 |
Accuracy | > 99% | Shelf life | Two Years |
Type | Pathological Analysis Equipments | Technology | Quantitative kit |
SUMMARY
Gastric helicobacter pylori infection is closely related with chronic gastritis, gastric ulcer, gastric adenocarcinoma, gastric mucosa associated lymphoma, H.p ylori infection rate of about 90% in gastritis, gastric ulcer, duodenal ulcer and gastric cancer patients. The world health organization has identified h. pylori as the first type of cancer-causing factor and is clearly a risk factor for gastric cancer.H.pylori detection is of great value in the diagnosis of h. pylori infection.The test based on fluorescence immunochromatographic assay analysis technics, which can give a result within 15 minutes.
PRINCIPLE OF THE PROCEDURE
The strip has anti HP coating antibody on test region, which is fastened to membrane chromatography inadvance. Lable pad is coated by fluorescence labeled anti HP antibody in advance. When testing positive sample, the HP in sample can be mixed with fluorescence labeled anti HP antibody, and form immune mixture. As the mixture is allowed to migrate along the test strip, the HP conjuga te complex is captured by anti HP coating antibody on the membrane and forms complex. The fluorescence intensity is positively correlated with the HP content. The HP in sample can be detected by fluorescence immunoassay analyzer.
RELATED PRODUCTS
1.H.Pylory antibody rapid test
2.Diagnostic kit for Fecal Occult Blood
Tags :