Diagnostic Kit for Quantitative Carbohydrate Antigen 125
1. Usage
This kit is applicable to in vitro quantitative detection of Carbohydrate Antigen 125 (CA 125) in human serumsamples. The kit only provides test result of Carbohydrate Antigen 125 (CA 125) . The obtained result shall be analyzed in combination with other clinical information. It must only be used by healthcare professionals.
2. PRODUCT SPECIFICATION
| Model No. | CA125 |
| Methodology | Fluorescence Immunochromatographic Assay |
| Sample Type | serum/plasma |
| Time to Result | 10-15mins |
| Storage | 2~30 ℃/36~86℉ |
| Shelf Life | 24 months |
| Certificate | ISO13485 |
| MAIN KIT COMPONENTS: *Test device *solution *Instructions for Use |
Packing: *25 test /kit *Aluminum foil bag labeling *shrink wrap |
3.TEST METHOD
| 1 | Read the instruction for use and test operation manual completely before the test and restore the reagent to room temperature before the test. Do not perform the test without restoring the reagent to room temperature to avoid affecting the accuracy of the test results. |
| 2 | Select standard test mode of WIZ-A101 portable immune analyzer |
| 3 | Open the aluminum foil bag package of reagent, and take out the test device; |
| 4 | Horizontally insert the test device into the slot of immune analyzer; |
| 5 | On home page of operation interface of immune analyzer, click “Standard” to enter test interface; |
| 6 | Click “QC Scan” to scan the QR code on inner side of the kit; input kit related parameters into instrument, and select sample type; Note: Each batch number of the kit shall be scanned for one time. If the batch number has been scanned, then skip this step; |
| 7 | Check the consistency of “Product Name”, “Batch Number” etc. on test interface with information on the kit label; |
| 8 | After information consistency is confirmed, take out sample diluents, add 80µL of serum/plasma sample, and sufficiently mix;Add 80µL of above mixed solution into the sample hole of test device; |
| 9 | After complete sample addition, click “Timing” and remaining test time will be automatically displayed on the interface. |
| 10 | Immune analyzer will automatically complete test and analysis when test time is reached. |
| 11 | Result calculation and display After test by immune analyzer is completed, test result will be displayed on test interface or can be viewed through “History” on home page of operation interface. |
4.Importance of CA125 Detection